marantz dp870 manual pdf

The Marantz DP870 is a professional-grade digital audio processor designed for high-end audio applications, featuring advanced digital signal processing, multiple input/output configurations, and comprehensive control options. Below are key sections covering features, installation, operation, specifications, and technical details.

1. Features Overview 2. Installation Guide 3. Initial Setup 4. Technical Specifications 5. Controls and Functions 6. Connection Diagrams 7. Operation Modes 8. Advanced Settings 9. Maintenance 10. Compliance Information 11. Troubleshooting Guide

Features Overview

Key components: Digital audio processor, remote control capability, multiple digital/analog inputs, balanced outputs, DSP processing, and network connectivity options.

FeatureDescription
Digital InputsAES/EBU, S/PDIF, Toslink optical
Analog InputsXLR balanced, RCA unbalanced
OutputsXLR balanced analog, digital outputs
Processing24-bit/192kHz DAC, DSP algorithms
ControlRS-232, Ethernet, IR remote
Power SupplyInternal switching power supply
DisplayLED status indicators
Sample Rates32kHz to 192kHz supported
FiltersSelectable digital filters
Setup MemoryMultiple configuration presets

Installation Guide

Unpack and inspect all components. Place unit in well-ventilated area.

  1. Connect audio sources: Use appropriate digital or analog inputs
  2. Connect outputs: Route to amplifiers or recording equipment
  3. Network connection: Connect Ethernet for remote control
  4. Power connection: Use supplied power cable
  5. Rack mounting: Use optional rack ears for installation

WARNING! Ensure proper ventilation; do not block cooling vents. Use certified cables for optimal performance.

Initial Setup

Power on unit; configure basic settings via front panel or remote.

  1. Input selection: Choose primary audio source
  2. Output configuration: Set levels and routing
  3. Sample rate: Configure for source material
  4. Filter selection: Choose appropriate digital filter
  5. Preset saving: Store configurations for quick recall

CAUTION! Allow unit to reach room temperature before operation. Handle with care during setup.

Technical Specifications

Controls and Functions

Front panel: Power switch, input selection, menu navigation, display. Remote control: All front panel functions plus additional presets.

Menu System: Input configuration, output settings, DSP parameters, system setup. Navigation via rotary encoder and function buttons.

Input Settings: Source selection, format detection, sample rate display. Output Settings: Level adjustment, polarity, mute functions. System: Firmware version, factory reset, network configuration.

Connection Diagrams

Digital sources: Connect via AES/EBU, S/PDIF, or Toslink. Analog sources: Use XLR or RCA inputs. Outputs: Connect to amplifiers or recorders.

  1. Turn off all equipment before making connections
  2. Use quality cables appropriate for signal type
  3. Ensure proper impedance matching for digital connections
  4. Verify signal flow from source to destination

Tip: Use balanced connections for long cable runs to minimize noise.

Operation Modes

Supports various operational configurations for different applications.

  1. Stereo mode: Standard 2-channel operation
  2. Dual mono: Independent channel processing
  3. Pass-through: Digital signal without processing
  4. Processing modes: Apply DSP algorithms as needed
  5. Preset recall: Quick configuration changes
  6. Remote operation: Control via network or IR
  7. Standby modes: Power saving options
  8. Monitor mode: Input/output comparison

WARNING! Do not operate with covers removed. Allow proper warm-up time for optimal performance.

Advanced Settings

Digital filter selection: Choose from multiple filter types for different sonic characteristics. Level calibration: Fine-tune output levels for system matching. Delay settings: Apply digital delays for time alignment.

Maintenance

Keep unit clean and dust-free. Use soft, dry cloth for exterior cleaning. Ensure adequate ventilation around unit.

CAUTION! No user-serviceable parts inside. Refer servicing to qualified personnel only.

Compliance Information

CE compliant: Meets European safety and EMC standards. FCC Part 15: Class A digital device. RoHS compliant: Free of hazardous substances. For technical support, contact Marantz professional audio division or visit www.marantzpro.com.

Troubleshooting Guide

SymptomPossible CauseCorrective Action
No audio outputInput selection/mutingCheck input source; verify mute status; inspect cables
Digital lock issuesSample rate mismatchVerify source sample rate; check cable quality
Noise in outputGround loops/cablesUse balanced connections; check grounding
Remote control not workingBatteries/obstructionsReplace batteries; ensure line of sight to IR sensor
Unit not powering onPower supply/issuesCheck power cable; verify outlet function

Reset Procedure: Hold setup button during power-on for factory reset.

Service Information: Contact authorized Marantz service center for repairs.

Marantz DP870 User Manual © - All Rights Reserved 2025