Marantz CD67SE Service Manual

The Marantz CD67SE is a high-quality CD player featuring advanced digital-to-analog conversion, precision laser mechanism, servo control systems, and comprehensive audio output options. This service manual provides detailed technical information for qualified service personnel including schematics, alignment procedures, troubleshooting guides, and replacement part specifications.

1. Technical Specifications 2. Block Diagram Overview 3. Circuit Descriptions 4. Mechanical Assembly 5. Alignment Procedures 6. Test Points & Measurements 7. Troubleshooting Guide 8. Parts List 9. PCB Layouts 10. Safety Precautions 11. Service Notes

Technical Specifications

Complete technical specifications for the Marantz CD67SE CD player system.

ParameterSpecification
Frequency Response2Hz - 20kHz (±0.5dB)
Signal-to-Noise Ratio>100dB
Dynamic Range>95dB
Total Harmonic Distortion<0.003%
Channel Separation>90dB (1kHz)
Output Voltage2.0V RMS
Power RequirementsAC 120V, 60Hz / 230V, 50Hz
Power Consumption15W
Dimensions (W×H×D)440×95×315 mm
Weight4.5 kg

Block Diagram Overview

System architecture and signal flow description.

  1. Laser Pickup Assembly: Reads digital data from CD surface
  2. RF Amplifier: Processes raw signal from pickup
  3. Servo Control: Manages focus, tracking, and spindle motors
  4. Digital Signal Processor: Decodes EFM signal and error correction
  5. D/A Converter: 1-bit Delta-Sigma conversion system
  6. Analog Output Stage: Low-pass filtering and amplification
  7. Power Supply: Multiple regulated voltage rails
  8. Control System: Microprocessor and display interface

WARNING! Only qualified technicians should perform service procedures. High voltages present.

Circuit Descriptions

Detailed analysis of major circuit sections.

  1. Laser Power Control: Automatic power calibration circuit
  2. Focus & Tracking Servo: Closed-loop control systems
  3. Spindle Motor Drive: Constant linear velocity control
  4. Digital Filter: 8-times oversampling digital filter
  5. D/A Conversion: 1-bit MASH conversion technology
  6. Analog Output: Dual differential configuration
  7. Power Supply: Transformer with multiple secondary windings
  8. Microprocessor Control: System timing and user interface

CAUTION! Static-sensitive components require proper handling procedures.

Mechanical Assembly

Alignment Procedures

Factory alignment and adjustment procedures for optimal performance.

Required Equipment: Oscilloscope, test CD, digital multimeter, alignment jigs

RF Amplitude: Adjust for 1.2Vp-p at test point TP-RF. Focus Offset: Adjust for symmetrical eye pattern. Tracking Balance: Center tracking error signal. PLL Frequency: Set to 4.3218 MHz ±10Hz. Output Level: Calibrate for 2.0V RMS at 0dB recording.

Test Points & Measurements

Critical test points and expected measurement values.

  1. Power up unit and allow stabilization
  2. Verify all power supply voltages within ±5%
  3. Check laser power with optical power meter
  4. Monitor RF signal quality and amplitude
  5. Verify servo lock and stability
  6. Measure audio output characteristics

Tip: Use factory test CD for all audio performance measurements.

Troubleshooting Guide

Common failure symptoms and diagnostic procedures.

SymptomPossible CauseCorrective Action
No disc recognitionLaser failure/dirty lensClean lens; check laser power; replace pickup if necessary
Disc spins but no audioDSP or D/A failureCheck digital signal path; verify clock signals; test D/A converter
Intermittent playbackServo instabilityAdjust focus/tracking gain; check power supply ripple
No displayDisplay driver or microprocessorCheck display voltages; verify microprocessor operation
Motor not spinningDriver circuit or motorTest motor directly; check driver IC voltages

WARNING! Laser radiation - do not view directly with optical instruments.

Parts List

Critical replacement components and part numbers.

PCB Layouts

Printed circuit board diagrams and component locations.

CAUTION! Use proper soldering techniques to avoid PCB damage.

Safety Precautions

Essential safety procedures for service personnel.

Always disconnect AC power before servicing. Use isolation transformer when testing live circuits. Observe ESD precautions with sensitive components. Replace safety-critical components with exact specifications. Verify all covers and shields are properly reinstalled.

Service Notes

Additional technical information and service tips.

ComponentService NoteReference
Laser PickupKSS-213C replacement procedureSection 5.2
Power SupplyVoltage regulation adjustmentSection 4.7
Servo ICGain adjustment pointsSection 6.3
D/A ConverterPerformance verificationSection 7.4
MicroprocessorReset and initializationSection 8.1

Service Support: Contact authorized Marantz service centers for technical assistance and genuine replacement parts.

Marantz CD67SE Service Manual © - All Rights Reserved 2025