The Marantz CD67SE is a high-quality CD player featuring advanced digital-to-analog conversion, precision laser mechanism, servo control systems, and comprehensive audio output options. This service manual provides detailed technical information for qualified service personnel including schematics, alignment procedures, troubleshooting guides, and replacement part specifications.
Complete technical specifications for the Marantz CD67SE CD player system.
| Parameter | Specification |
|---|---|
| Frequency Response | 2Hz - 20kHz (±0.5dB) |
| Signal-to-Noise Ratio | >100dB |
| Dynamic Range | >95dB |
| Total Harmonic Distortion | <0.003% |
| Channel Separation | >90dB (1kHz) |
| Output Voltage | 2.0V RMS |
| Power Requirements | AC 120V, 60Hz / 230V, 50Hz |
| Power Consumption | 15W |
| Dimensions (W×H×D) | 440×95×315 mm |
| Weight | 4.5 kg |
System architecture and signal flow description.
WARNING! Only qualified technicians should perform service procedures. High voltages present.
Detailed analysis of major circuit sections.
CAUTION! Static-sensitive components require proper handling procedures.
Factory alignment and adjustment procedures for optimal performance.
Required Equipment: Oscilloscope, test CD, digital multimeter, alignment jigs
RF Amplitude: Adjust for 1.2Vp-p at test point TP-RF. Focus Offset: Adjust for symmetrical eye pattern. Tracking Balance: Center tracking error signal. PLL Frequency: Set to 4.3218 MHz ±10Hz. Output Level: Calibrate for 2.0V RMS at 0dB recording.
Critical test points and expected measurement values.
Tip: Use factory test CD for all audio performance measurements.
Common failure symptoms and diagnostic procedures.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No disc recognition | Laser failure/dirty lens | Clean lens; check laser power; replace pickup if necessary |
| Disc spins but no audio | DSP or D/A failure | Check digital signal path; verify clock signals; test D/A converter |
| Intermittent playback | Servo instability | Adjust focus/tracking gain; check power supply ripple |
| No display | Display driver or microprocessor | Check display voltages; verify microprocessor operation |
| Motor not spinning | Driver circuit or motor | Test motor directly; check driver IC voltages |
WARNING! Laser radiation - do not view directly with optical instruments.
Critical replacement components and part numbers.
Printed circuit board diagrams and component locations.
CAUTION! Use proper soldering techniques to avoid PCB damage.
Essential safety procedures for service personnel.
Always disconnect AC power before servicing. Use isolation transformer when testing live circuits. Observe ESD precautions with sensitive components. Replace safety-critical components with exact specifications. Verify all covers and shields are properly reinstalled.
Additional technical information and service tips.
| Component | Service Note | Reference |
|---|---|---|
| Laser Pickup | KSS-213C replacement procedure | Section 5.2 |
| Power Supply | Voltage regulation adjustment | Section 4.7 |
| Servo IC | Gain adjustment points | Section 6.3 |
| D/A Converter | Performance verification | Section 7.4 |
| Microprocessor | Reset and initialization | Section 8.1 |
Service Support: Contact authorized Marantz service centers for technical assistance and genuine replacement parts.