The Marantz CD5003 is a high-quality CD player featuring advanced digital-to-analog conversion, high-current discrete output stages, proprietary HDAM (Hyper Dynamic Amplifier Module) circuits, and Marantz's unique CD mechanism. This service manual provides comprehensive technical information for service technicians, including schematics, alignment procedures, parts lists, and troubleshooting guidelines for the CD5003 audio component.
Complete technical specifications for the Marantz CD5003 CD player.
| Parameter | Specification |
|---|---|
| Frequency Response | 2Hz - 20kHz (±0.3dB) |
| Signal-to-Noise Ratio | 110dB |
| Dynamic Range | 100dB |
| Total Harmonic Distortion | 0.002% |
| Channel Separation | 105dB (1kHz) |
| Output Voltage | 2.0V RMS |
| Digital Output | Coaxial, 0.5Vp-p/75Ω |
| Power Consumption | 18W |
| Dimensions (W×H×D) | 440×105×345mm |
| Weight | 6.5kg |
System architecture and signal flow description.
WARNING! High voltages present in power supply section. Use appropriate safety precautions.
Step-by-step disassembly procedure for service access.
CAUTION! Always disconnect AC power before disassembly. Handle ribbon cables carefully to avoid damage.
Factory alignment and adjustment procedures.
Laser Power Adjustment: Monitor test point TP1 while adjusting VR101 for 0.45V ±0.02V
Focus Bias: Adjust VR102 for maximum RF amplitude at TP2
Tracking Balance: Adjust VR103 for symmetrical eye pattern
Output Level: Adjust VR104 for 2.0V RMS at 1kHz test tone
Clock Frequency: Verify 16.9344MHz crystal frequency at IC201 pin 15
Critical test points and expected measurements.
Tip: Use oscilloscope with 10:1 probe for RF measurements.
Critical components and replacement part numbers.
WARNING! Use only specified replacement parts to maintain performance and safety.
Systematic troubleshooting procedures for common faults.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No power | Fuse, power switch, transformer | Check F101, measure primary voltage, test power switch |
| No disc recognition | Laser, servo IC, focus circuit | Check laser emission, focus search operation, RF amplitude |
| No audio output | D/A converter, output stage | Verify digital signal, test D/A IC, check HDAM circuits |
| Tracking errors | Lens, tracking coil, servo | Clean lens, measure coil resistance, check servo IC |
| Display issues | Display driver, VFD, power | Check filament voltage, segment voltages, driver IC |
Reset: Power cycle resets microprocessor. Factory reset not available.
Printed circuit board layouts and component locations.
Main PCB: Double-sided with ground plane. Component designations follow standard numbering.
Power Supply PCB: Single-sided with high-voltage isolation.
Display PCB: Flexible connections to front panel.
CAUTION! Observe ESD precautions when handling PCBs.
Essential safety and service guidelines.
Always disconnect AC power before servicing. Use isolation transformer when testing live circuits. Observe ESD precautions with sensitive ICs. Use specified lubricants for mechanical parts. Calibrate after component replacement.
WARNING! High voltages present. Qualified technicians only.
Software and firmware details.
Microprocessor: Custom Marantz firmware version 1.2. No user-upgradeable firmware. Service mode access: Hold STOP and PLAY during power-on. Factory service required for firmware updates.
Copyright © 2008 Marantz. For technical support, contact authorized Marantz service centers.