Marantz CD 52 MKII Service Manual

The Marantz CD 52 MKII is a high-quality CD player featuring advanced digital audio technology, precision laser mechanism, high-resolution digital-to-analog conversion, remote control operation, multiple output options, and robust construction. This service manual provides comprehensive technical information for service technicians, including schematics, alignment procedures, troubleshooting guides, and replacement parts information.

1. Technical Specifications 2. Block Diagram Overview 3. Disassembly Instructions 4. Circuit Descriptions 5. Alignment Procedures 6. Troubleshooting Guide 7. Parts List 8. Schematics 9. PCB Layouts 10. Service Notes 11. Safety Precautions

Technical Specifications

Complete technical specifications for the Marantz CD 52 MKII CD player system.

ParameterSpecification
Audio Channels2 (Stereo)
Frequency Response20Hz - 20kHz ±0.5dB
Signal-to-Noise Ratio>100dB
Dynamic Range>95dB
Total Harmonic Distortion<0.005%
Channel Separation>90dB at 1kHz
Output Voltage2.0V RMS
Digital OutputCoaxial, Optical
Power Requirements220-240V AC, 50/60Hz
Power Consumption15W
Dimensions (WxHxD)440 x 95 x 310 mm
Weight5.2 kg

Block Diagram Overview

System block diagram showing signal flow and major components.

  1. Laser Pickup Assembly: Reads digital data from CD surface
  2. RF Amplifier: Amplifies RF signal from pickup
  3. Servo Control: Focus, tracking, and spindle motor control
  4. Digital Signal Processor: EFM demodulation, error correction
  5. Digital Filter: Oversampling digital filter
  6. D/A Converter: 16-bit digital-to-analog conversion
  7. Analog Output Stage: Low-pass filtering and amplification
  8. Power Supply: Multiple voltage regulation
  9. Microcontroller: System control and user interface

NOTE: Refer to schematic diagrams for detailed circuit connections.

Disassembly Instructions

Step-by-step disassembly procedure for service access.

  1. Power off and disconnect AC power cord
  2. Remove top cover: Remove 6 screws from rear and sides
  3. Remove front panel: Disconnect ribbon cables carefully
  4. Remove main PCB: Disconnect all connectors and remove mounting screws
  5. Access mechanism: Remove mechanism mounting screws
  6. Laser unit replacement: Disconnect flex cable and remove unit

WARNING! Always discharge capacitors before working on power supply section.

Circuit Descriptions

Alignment Procedures

Factory alignment procedures and test points.

Required Test Equipment: Oscilloscope, audio analyzer, test CD, digital voltmeter

RF Level Adjustment: Adjust VR101 for 1.2Vp-p RF signal at TP101

Focus Gain: Adjust VR102 for optimal focus servo response

Tracking Gain: Adjust VR103 for stable tracking

PLL Adjustment: Set VC101 for 4.3218MHz at TP102

Output Level: Verify 2.0V RMS at outputs with 0dB test signal

CAUTION! Use factory test CDs and follow procedures exactly.

Troubleshooting Guide

Common symptoms and diagnostic procedures.

SymptomPossible CauseCorrective Action
No disc recognitionLaser pickup, RF ampCheck RF waveform; replace pickup if <0.8Vp-p
Disc spins but no audioDigital processor, D/A converterCheck LRCK, DATA, BCK signals; verify D/A operation
Intermittent playbackServo circuits, power supplyMonitor servo error signals; check power supply voltages
No displayMicrocontroller, display driverCheck +5V supply; verify microcontroller operation
Hum in audioGround loops, power supplyCheck grounding; verify power supply filtering
Remote control not workingRemote sensor, microcontrollerTest remote sensor output; check microcontroller IR input

Parts List

Critical replacement parts and components.

Part NumberDescriptionQty
KSS-240ALaser Pickup Assembly1
CXA1372QServo Signal Processor1
CXD2500BQDigital Signal Processor1
SM5872BMD/A Converter1
NJM4558Dual Operational Amplifier2
HD6433256F10Microcontroller1
LA6531Motor Driver IC1
PS-152Power Transformer1

NOTE: Always use genuine Marantz replacement parts.

Schematics

Complete circuit schematics for all sections.

  1. Main System Block Diagram
  2. Power Supply Circuit
  3. Laser RF Amplifier
  4. Servo Control Circuits
  5. Digital Signal Processing
  6. D/A Converter and Analog Output
  7. Microcontroller and Display
  8. Remote Control Receiver

Tip: Refer to schematic diagrams for component values and test points.

PCB Layouts

Printed circuit board layouts and component locations.

CAUTION! Handle PCBs carefully to avoid damage to traces.

Service Notes

Important service tips and modifications.

  1. Laser safety: Never look directly into laser beam
  2. ESD protection: Use grounded wrist strap when handling ICs
  3. Soldering: Use temperature-controlled soldering iron
  4. Cleaning: Use isopropyl alcohol for contact cleaning
  5. Lubrication: Apply specified grease to sliding mechanisms
  6. Alignment: Record original positions before adjustments

WARNING! Laser products are classified as Class 1 laser devices.

Safety Precautions

Essential safety information for service personnel.

HazardPrecaution
Electric ShockDisconnect power before servicing; discharge capacitors
Laser RadiationDo not expose eyes to laser beam; follow laser safety procedures
Heat DamageAllow unit to cool before handling; use heat sinks when soldering
Component DamageUse proper tools; avoid static discharge; follow ESD procedures
Mechanical InjuryWatch for sharp edges; secure unit during service

Service Support: Contact Marantz technical support for complex issues.

Marantz CD 52 MKII Service Manual © - All Rights Reserved 2025